
$202.99
See if it's really the one
Search with this product to compare it, find similar styles, or turn up something better before deciding.
True 831971 OEM Defrost Timer The True 831971 Defrost Timer is an OEM refrigeration control component designed for compatible True Manufacturing commercial refrigerators and freezers. The timer works within the equipment's defrost-control system to provide the timed switching sequence required between normal refrigeration operation and the applicable defrost cycle. Proper defrost timing is critical to commercial refrigeration performance. Excessive frost accumulation on the evaporator can restrict airflow, reduce heat transfer, increase cabinet temperature, and force the refrigeration system to operate longer than intended. A timer that stalls, fails to advance, switches intermittently, or develops electrical damage can contribute to repeated icing and abnormal defrost operation. When qualified diagnosis confirms defrost-timer replacement is required, using the correct True OEM 831971 helps restore the defrost-control configuration intended for compatible True refrigeration equipment. OEM Part Details Manufacturer: True Manufacturing OEM Part Number: 831971 MPN: 831971 SKU: 831971 Part Type: Defrost Timer Application: Commercial Refrigeration Equipment System: Refrigeration / Defrost Control System Function: Timed Refrigeration-to-Defrost Switching What the True 831971 Defrost Timer Does The True 831971 defrost timer manages the timing relationship between normal cooling operation and the applicable defrost sequence. At the intended interval, the timer changes the state of the appropriate electrical circuit so the refrigeration equipment can enter defrost. Once the scheduled defrost period is complete, the control allows the equipment to return toward normal refrigeration operation according to the cabinet design. Proper timer operation helps support: Scheduled defrost operation Controlled transition between refrigeration and defrost Reduced excessive evaporator frost buildup Proper evaporator airflow Consistent cabinet-temperature performance Normal refrigeration-system cycling Dependable commercial refrigeration operation Common Signs of a Defrost Timer Problem Qualified commercial refrigeration technicians may inspect the True 831971 when troubleshooting conditions such as: Evaporator repeatedly develops heavy frost or ice Equipment does not enter defrost when expected Equipment enters defrost but does not return to cooling correctly Timer mechanism does not advance Timer operates intermittently Cabinet temperature rises because evaporator airflow is restricted Refrigeration cycle does not resume normally Timer contacts do not switch consistently Electrical terminals show signs of overheating Wiring or connectors are loose, burned, or damaged Manual timer advancement changes equipment operation unexpectedly These symptoms do not automatically confirm timer failure. Defrost heaters, termination controls, temperature sensors, evaporator fan motors, wiring, door sealing, drainage, control components, and refrigeration-system conditions can create similar symptoms. The complete defrost system should be diagnosed before replacing the timer. Diagnosing an Iced Evaporator A heavily iced evaporator does not automatically mean the True 831971 has failed. Frost accumulation can originate from several refrigeration, airflow, door-sealing, and defrost-system conditions. Technicians may need to inspect: Defrost timer operation Defrost heater operation where applicable Defrost termination controls Temperature sensors Evaporator fan operation Evaporator airflow Door gasket condition Door closing and alignment Air infiltration Drainage from the evaporator area Refrigeration-system performance Identifying the actual cause of frost accumulation helps prevent unnecessary replacement of a functioning timer. Defrost Timer vs. Defrost Heater The defrost timer and defrost heater perform different functions within the refrigeration system. Defrost Timer: Controls when the applicable defrost sequence occurs. Defrost Heater: Supplies heat used to remove frost from the evaporator where electric defrost is used. If the timer changes states correctly but the evaporator remains heavily iced, the heater circuit and related termination components should also be tested. Defrost Timer vs. Defrost Termination Control Some True refrigeration systems use additional temperature-responsive controls to help manage or terminate the defrost sequence. These components serve a different function from the timer and should not be treated as interchangeable. When diagnosing abnormal defrost operation, technicians may need to evaluate: True 831971 timer operation Defrost termination thermostat or switch Evaporator temperature sensors Defrost heaters Associated wiring Control relays or contactors where applicable Fan Operation After Defrost Evaporator fan operation can be closely related to the defrost sequence. If fans fail to resume normally after defrost, technicians should evaluate the complete control system rather than replacing the timer based solely on the fan symptom. Possible areas to inspect include: Defrost timer Fan-delay controls where applicable Evaporator temperature controls Fan motor Fan wiring Ice obstruction Control relays Manual Timer Advancement During Diagnosis Where the timer design permits manual advancement, a qualified technician may use that feature as part of system diagnosis to determine whether the connected refrigeration and defrost circuits respond when the timer changes states. If manually advancing the timer changes equipment operation, additional electrical testing can help determine whether the timer mechanism, timer motor, wiring, or another defrost component is responsible. Manual advancement should follow appropriate service procedures and should not replace complete electrical diagnosis. Inspect Wiring & Electrical Connections Before installing a replacement True 831971, inspect the original timer and surrounding electrical connections carefully. Look for: Loose terminals Burned connectors Discolored wiring Melted insulation Corrosion Damaged terminal ends Evidence of electrical arcing Overheated timer connections A high-resistance electrical connection can generate heat and damage the replacement timer if the underlying problem is not corrected. Technician Checks Before Ordering Before replacing the True 831971 defrost timer, verify: OEM part number 831971 Complete True equipment model Equipment serial number Original timer identification Equipment supply voltage Timer terminal arrangement Wiring configuration Mounting arrangement Defrost-system design Defrost heater condition where applicable Defrost termination-control condition Evaporator fan operation Associated wiring and connectors OEM part-number verification should be the primary identification method. Defrost timers can appear nearly identical while having different electrical ratings, timing sequences, terminal layouts, switching configurations, and equipment applications. Commercial Refrigeration Applications True commercial refrigerators and freezers are used in demanding foodservice environments where dependable cooling and defrost operation are essential. Restaurants Commercial kitchens Convenience stores Supermarkets Hotels Schools Hospitals Universities Institutional kitchens Corporate cafeterias Catering operations Commercial foodservice facilities Installation & Electrical Safety Notes Disconnect electrical power before servicing commercial refrigeration equipment and follow applicable True Manufacturing service procedures. Before removing the original 831971 timer, photograph or document every electrical connection, terminal position, mounting point, and timer orientation. Compare the replacement timer with the original component before transferring wiring. Inspect related defrost components, wiring, connectors, and evaporator fan components for faults that may have contributed to the original problem. After installation, restore power and operate the equipment through the appropriat
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2026
$202.99