
$12,400.00
See if it's really the one
Search with this product to compare it, find similar styles, or turn up something better before deciding.
Target imaging systems for SFR-Fit for CMS SFR-Fit for CMS can measure the MTF of various imaging systems, including rear view, around view, and electronic mirrors. Measurement system configuration Measurement Procedure The measurement procedure is shown below. The measurement time is about 20 minutes with one camera system (three ROIs). Measurement example (video) Measurement example with an electronic mirror Compared to near the center, the MTF decreases in the left and right areas where the image height is high. Technical Explanations Measurement Algorithm Uses the same measurement method as SFR-Fit for cameras, the only difference with the normal SFR-Fit is that the chart shown on the display is recaptured by the reference camera. CMS measurement (total characteristics of camera +monitor) Examples of images captured with the reference camera(ROI only). Reference Camera Specification Unit Specification Remarks Lens f=16mm Supports 10MPixel Remote Control(Focus, Iris) Image Sensor 1/1.8inch 5MPixel(2448×2048) Grayscale The interface is USB 3.0 Lens hood fixture Working Distance 100mm or 64mm Made by Leader Electronics(3D Print) Lens Hood For this measurement, a lens hood is used to keep the reference camera and display in the correct position. Users need to place the lens hood tightly against the display. Lens hood type Maximum pixel density WD100mm 199 dpi WD64mm 300 dpi Reference camera and display pixel ratio When measuring the MTF on a display using a sine wave bar chart, it is known that if the pixel ratio is not high enough, an error in the MTF measurement can occur. This reference camera is designed to have a pixel ratio of at least 5 times. Reference camera MTF compensation To compensate for the reduction in MTF due to the reference camera, the measurement result is divided by the MTF of the reference camera. The MTF of the reference camera is measured in advanced and isincluded with the product at the time of shipment as an MTF compensation file. SFR-Fit CMS MTF graph Parameters that are essential for measurement To define the spatial frequencies on the display, users must enter the parameters of the test display. Parameter Estimation Function Monitor PH [Pixel] and Surface Depth [mm], which are difficult to determine, can be estimated using the parameter estimation function. Unit of spatial frequency SFR-Fit CMS can express the spatial frequency on the display surface from the set display specifications and shooting magnification. These units are useful for knowing the performance balance between the camera and the display. Measurements near Nyquist frequency SFR-Fit CMS uses a sine wave bar chart to measure the MTF of a display, but when the pixel ratio is about 5 times, the contrast measurement error is up to 2%. Furthermore, due to the measurement principle, the measurement value is unstable near the Nyquist frequency. For this reason, the software skips the measurement points between 0.475 and 0.525C/P. Measurement Repeatability Because SFR-Fit uses a sine wave bar chart and MTF measurement using the least squares method, it can perform measurements that are less affected by the pixel structure of the display or image processing. As shown below, the repeatability of the measurement values is good, which is why we allow for measurement error. MTF repeatability of rear view monitor (measured 15 times). The graphs are almost identical.
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2026
$12,400.00