Laser] Maximum Power: 1040mW ± 20% Beam Divergence: 12° x 30° Nominal Optical Hazard Distance (NOHD): 60cm Cord Length: 60" Application Information: BEFORE TREATMENT Check the patient for contraindications. Before applying laser therapy, it is necessary to prepare the patients skin to allow the laser light to reach the target tissue better and to reduce skin irritation, by doing the following: Clean the area where the head of the laser will be positioned with soap and water or alcohol. Make sure to dry the area well before starting laser application. Both operator and patient MUST wear the PROTECTIVE GLASSES. DURING TREATMENT Frequently ask to ensure patients are not experiencing undesired effects from treatment. If necessary the treatment will have to be adapted. The amplitude can be reduced or the continuous mode can be changed to pulsed mode or vice versa. Do not look directly into the laser or remove protective glasses prior to treatment ending. AFTER TREATMENT Ensure the laser output has stopped before removing the protective glasses from the patient and treating clinician. Observe the treatment area to ensure no undesired effects have occurred. Tell the patient to inform the clinician should they have any adverse reactions. Treatment Tips: CONTACT For most effective results, the applicator should be in contact with the patient's skin and may require multiple applications around the treatment area. APPLICATOR SELECTION For very small treatment areas, treat with the single diode applicator. For areas that are sensitive, use the single applicator first, then use the cluster applicator. PRE & POST TREATMENT COLD: If treating with cold therapy as part of the treatment regimen, apply cold therapy prior to laser treatment as it reduces the energy that is removed from the area and slows the flow of red blood cells. HOT: If treating with hot therapy as part of the treatment regimen, apply heat after laser treatment as it increases the energy and can be removed from the area by speeding up the flow of red blood cells. Frequently Asked Questions: "Aren't Class IV lasers better than Class IIIb because they have more power?" No. The majority of clinical research surrounding low-level laser therapy has been done using Class IIIb lasers. That research has shown positive outcomes for quicker tissue healing, inflammation reduction, and pain management. "Should I be concerned that the laser will burn my patients?" Class IV lasers have a higher risk for patient burns because they were originally developed for surgery & thermal therapy applications. Class IIIb lasers are non-thermal so the risk is minimal. "Clinical laser therapy devices are very costly... Why should I buy yours?" Class IV & other Class 3b laser units may indeed be costly and also do not typically come with all necessary accessories, like an applicator. The TheraTouch LX2 is the only unit on the market equipped standard with an applicator and all necessary parts to begin treatment right away, and also supported by Richmar's industry-leading 3-year manufacturer warranty, so rest assured you will always be covered and well taken care of should any technical issues ever arise. "I don't know much about laser therapy and how best to apply the TheraTouch LX2 device..." No worries! The heart of the LX2 is a menu-driven touchscreen interface to guide users through treatment set-up each step of the way. Research-based clinical protocols also aid in quick set-up: Just select the patient's condition or treatment goal, and you are ready to go! Any questions, or assistance needed, along the way, just ask. "I am not familiar with Richmar. Why should I trust this manufacturer and product?" Richmar has been a leading US-based manufacturer and distributor of physiotherapy modalities and supplies for over 65 years. After inventing the very first ultrasound/electrotherapy combination device in 1958, Richmar continues to be at the forefront of innovation and trust in the industry today. "I am concerned about initial set up and training for the device. Is there support available?" Absolutely! The TheraTouch LX2 comes ready-to-use right outside the box. Always refer to the Operation Manual first, and if any additional training is needed, just contact your dealer to coordinate and schedule a more formal training session. The goal is to ensure that when all is said and done, you know exactly how to use the product, and feel comfortable doing so. Your dealer will always be available should any questions ever arise. Package Contents: 1x Richmar TheraTouch LX2 Device 2x Laser Protective Goggles With Cleaning Cloth & Carrying Case 1x AC Power Cord 1x 9 Diode Cluster Applicator 1x User Manual Therapy Cart & Single Diode Applicator available as optional accessories.
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2025
$3,699.95