$116.00
See if it's really the one
Search with this product to compare it, find similar styles, or turn up something better before deciding.
The BX-3 is a single channel loop detector with two relay outputs and a rear 11-pin connector. It runs on 120 VAC (89 to 135 VAC, 4 W max). The housing is 3.00 x 1.75 x 4.30 in, excluding the connector. Output A runs Limited Presence or True Presence. Output B duplicates Output A, or gives a 250 ms pulse on entry, a pulse on exit, or a fault output. Settings are made with eight external DIP switches and an eight-position rotary sensitivity switch. It has four loop frequencies, a 2 second delay, sensitivity boost and detect memory for power drops up to 2 seconds. Relays are rated 6 A. Loop inductance range is 20 to 2000 µH. Fail-safe operation. Before You Order Replaces the discontinued Reno A&E AX-3 and B-3. The BX-4 is the 12/24 V AC/DC version. BX codes: 3 = 120 VAC, 4 = 12 VDC, 24 VDC or 24 VAC, 8 = 240 VAC; RO = reversed outputs, E = Euro outputs, S = fail-secure. Wires with an 11-pin harness such as the Reno A&E LMH802-4, or an SKT-11 socket base.
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2026