The Reno A&E H2-12-F is a single channel PC board loop detector with a 10-pin in-line female Molex connector centered on the 2.50 in side of the board. It runs on 10 to 14 VDC at 21 mA max. The board is 2.50 x 2.75 x 0.85 in, excluding the connector. It has three solid-state FET outputs. Output A is presence, set for fail-safe or fail-secure. Output B is presence or a pulse on entry or on exit. The third output signals a loop fail. Delay and extend times are 0, 2, 5 or 10 seconds. Eight sensitivity levels are set on a rotary switch, with four loop frequencies on DIP switches, sensitivity boost and detect memory for power drops up to 2 seconds. The detector tunes itself within 2 seconds of power-up or reset. It operates from -30°F to 180°F. Before You Order 12 VDC only. Check the operator board supply before installing. Fits operator boards with a 10-pin Molex detector header. The H1-12-F is the related Reno A&E board detector with the same connector position.