The Reno A&E H1-12-F is a single channel PC board loop detector with a 10-pin in-line female Molex connector (Molex 09-48-3105) centered on the 2.50 in side of the board. It runs on 12 VDC (10 to 14 VDC) at 21 mA max. The board is 2.50 x 2.75 x 0.85 in, excluding the connector. It has three solid-state FET outputs. Output A is presence, set for fail-safe or fail-secure. Output B is presence or a 250 ms pulse on entry or on exit. The third output signals a loop fail. Delay and extend times are 0, 2, 5 or 10 seconds. Eight sensitivity levels are set on a rotary switch, with four loop frequencies, sensitivity boost and detect memory. Loop inductance range is 20 to 1000 µH. It operates from -30°F to 180°F. Before You Order Direct plug-in replacement for the older Reno A&E H-12-F. F means female connector. Reno A&E also lists male (M) and low power (LP) versions. 12 VDC only. Fits operator boards with a 10-pin Molex detector header; check the board pinout and supply first.