
$19,999.00
See if it's really the one
Search with this product to compare it, find similar styles, or turn up something better before deciding.
Rapid temp. changing(humidity) test chamber also known as Environmental Stress Screening (ESS), AST (Accelerated Stress Testing), HALT (Highly Accelerated Stress Test), HASS (Highly Accelerated Stress Screening) or Burn-in test. ESS chamber is suitable for the whole product, parts and materials for high temperature, low temperature, high and low temperature circulating and temperature stress screening (ESS) test, and constant humidity and cyclic damp heat test. This type of machine mainly used to simulate the product after exposure to rapid change of ambient temperature and in certain humidity conditions, detecting the product features and the adapt change ability. Structural Features: Rapid Temperature Change Test Chamber Can set the temperature variable rate of the different stress screening Environmental stress screening test chamber Can perform a rapid temperature change (ESS), condensation test, high temperature and humidity test, temperature and humidity cycling test, etc. Meet the requirements of stress screening test for electronic equipment Switching temperature and average temperature these two kinds of test methods Stress screening (fast temperature change rate) 5/10/15deg C/min. Test hole: 1 piece of φ100mm test hole (located on the left side of chamber). Meet the requirements of stress screening test for electronic equipment MIL-STD-2164, MIL-344A-4-16, MIL-2134A-19, NABMAT-9492, GJB-1032-90, GJB/Z34-5.1.6, IPC-9701.... ETC. Can carry out the two test methods, temperature test and average temperature test With aluminum sheet test machine load capacity (non plastic load) Single machine can perform fast temperature change (ESS), condensation test, high temperature and humidity test, temperature and humidity cycling test, etc. Can screen the sample load with a large number Remote control via PC or phone. Complete real-time test curve analysis shows that no time limit Can be integrated with the E management system to monitor the management system Standard Compliance: IEC60068-2-1:2007 (GB/T2423.1-2008) Environmental testing – Part 2: Test methods – Tests A: Cold IEC60068-2-2:2007 (GB/T2423.2-2008) Environmental testing for electric and electronic products Test methods – Tests B: Dry Heat IEC 60068-2-14 2009 Environmental testing – Part 2-14: Tests -Test N: Change of temperature Safety features: Test sample overtemperature protection function. Circulation motor overload protection function. Compressor overload protection function. Compressor overpressure function. Heater/humidifier air burn protection function. Water shortage protection. Input power supply missing phase, reverse phase protection function. Lighting lamp / wire anti-condensation/no fuse independent protection switch in the secondary circuit. Electric leakage protection. Three color light alarm function. Test sample terminal and equipment chain control protection. Equipment fault shutdown, the cycle fan delay stop turn (delay can be set, 0 to 50min, default 5min). Non-metallic materials such as wire / cable / terminals / insulation materials / sound-absorbing materials (if sometimes) are made of flame-retardant materials. Specifications: Model KB6010 KB6025 KB6050 KB6100 Exterior Dimensions (5℃) 1100*900*1600mm 1200*1170*1950 1460*1200*2030 1580*1500*2120 Exterior Dimensions (10℃) 1100*1370*1740 1260*1510*2080 1460*1590*2220 1700*1600*2180 Exterior Dimensions (15℃) 1400*1770*1800 1460*1510*2080 1600*1780*2220 1800*1600*2180 Interior Dimensions 500*400*500mm (100L) 600*500*750mm (225L) 800*700*900mm (500L) 1000*1000*1000mm (1000L) Power (5℃) 7.5kw 12kw 20kw 26kw Power (10℃) 16kw 26kw 38kw 55kw Power (15℃) 22kw 33kw 60kw 88kw Cooling Method (5℃) Air cooling Air cooling Air cooling Air cooling or water cooling Cooling Method (10℃) Air cooling Air cooling or water cooling water cooling water cooling Cooling Method (15℃) Air cooling or water cooling water cooling water cooling water cooling Temp Adjustment Method Balanced temperature and humidity adjustment method (BTHC) PID intelligent adjustment Temperature Range -60℃ ~ 180℃ Humidity Range 20% ~ 98% R.H Temperature Uniformity ±1℃|Temperature Fluctuation: ±0.5℃ Humidity Uniformity ± 2% R.H|Humidity Fluctuation: ±1% R.H Heating Rate From -40℃ to 85℃,full range non-linear average 5℃/10℃/15℃/min, no load. (Optional) Cooling Rate From 85℃to -40℃ ,full range non-linear average 5℃/10℃/15℃/min, no load. (Optional) Inner Body Material SUS304 mirror stainless steel plate Shell Material SUS304 brushed stainless steel plate or anti-rust treatment cold rolled steel plate (plastic sprayed) Insulation Material Special ultra-fine glass wool + polyurethane foam for rapid temperature change test chamber Refrigeration Method Mechanical binary refrigeration method Refrigerator French Tecumseh compressor or German BOKE compressor Refrigerant R23, R404a, R507 Dupont Freon (United States) Heater Parts Nickel-chromium alloy stainless tube heater Humidifier Device Special stainless-steel humidifier for constant temperature change test chamber Blower System Centrifugal Fan Airflow Mode Broadband forced air circulation (top out and bottom in) Operation Interface LCD touch screen for rapid temperature change test chamber Power Supply 480V±10%, 50/60Hz 480V±10%, 50/60Hz 480V±10%, 50/60Hz 480V±10%, 50/60Hz
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2025
$19,999.00