
$7,081.00
See if it's really the one
Search with this product to compare it, find similar styles, or turn up something better before deciding.
Hyundai N700E Variable Frequency Drive , 1or3 Phase In, 230V, 60 HP, 170 Amps Constant Torque or 75 HP, 205 Amps Variable TorquE WORLDWIDE MOTOR CONTROLS Variable Frequency Drives Hyundai N700E Series High Performance Drives Model: N700E-450LF CT (Constant Torque, Heavy Duty) Rated Power 60 HP / 45 kW Rated Output Current (A) Rated Input Voltage Three Phase 200 ~240 VAC ± 10% 50/60 Hz ± 5% Rated Output Voltage Three Phase 200 ~240 VAC (corresponding to input voltage) Ambient Temperature -10 to 50°C (unit can be designed to function outside this range) Storage Temperature -20 to 60°C Ambient Humidity Below 90% RH Vibration 5.9N/s² (0.6G) 10 to 55Hz Location Under 1000m above sea level, indoors, away from corrosive gasses, dust, etc. General Product Specifications • Sensorless Vector PWM Control Method with V/Hz and Sensorless Vector Control Options • 0.01-400Hz Output Frequency Range • Frequency Accuracy: ± 0.01% Digital Reference, ± 0.1% Analog Reference • 0.1-3000 sec Accel/Decel with Selectable Profiles • DC Injection Braking • Built-in Dynamic Braking • IP20 Enclosure Rating • Heavy Duty: 150% Overload for One Minute, CT Applications • Normal Duty: 120% Overload for One Minute, VT Applications • Protective Functions, Including: Overcurrent, Electronic Thermal Overload, Inverter Overload, Braking Resistor Overload, Over-Voltage, Under-Voltage, Input Phase Loss, Output Short Circuit, Ground Fault, External Trips, Temperature Trip, Safety Function (option), Communication Error • Auto Tuning • PID Control, with Sleep and Wakeup Functions And more! Consult your WWE Representative to discuss your application! Analog Inputs Digital Inputs 6 Analog Output Digital Outputs 3 Control I/O 2 Input voltage: 0-10VDC (Input impedance 10KΩ) Input current: 4-20mA (Input impedance 250Ω) Intelligent Input Terminal Common I/O Commands: 2-Level Accel/Decel Multi-speed 1-4 (CF1-4) Command (2CH) PID Disable (PIDD) Analog Input Voltage/ PID Integral Reset (PIDIR) Current Transferring (AT) Remote UP/DOWN External Trip (EXT) Reset (RS) Forward Direction (FW) Reverse Direction (RV) Free-run Stop (FRS) Soft Lock (SFT) FW/RV (F/R) Start (STA) Jogging Run (JG) Stop (STP) Local Keypad Operation (O/R) Unattended Start Protection (USP) Local Terminal Input Operation (T/R) 2 Output frequency, output current, and output voltage Voltage output DC 0-10V; Current output DC 4-20mA 1x-Form C relay (Rated AC 250V 2.5A, DC 30V 3.0A); 2x-Intelligent Relay: RUN (Run signal) FA1 [Frequency arrival signal (at the set frequency)] FA2 [Frequency arrival signal (at or above the set frequency)] OL (Overload advanced notice signal) OD (Output deviation of PID signal) AL (Alarm signal) IndustryWorldWideElectric.net DRIVING & Controlling
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2026
$7,081.00