
$3,920.00
See if it's really the one
Search with this product to compare it, find similar styles, or turn up something better before deciding.
The all-in-one handheld CAN bus diagnostics device The GEMAC CANtouch® sets a new benchmark for physical and logical analysis of CAN bus systems. Similar to a smartphone in size, the CANtouch features an intuitive touchscreen for conducting CAN test functions. Complete with a rechargeable battery, the CANtouch is an excellent choice for mobile and flexible CAN diagnostics tasks. Take a quick tour here:...Video Features Tech Specs Documents Downloads The CANtouch® is an universal diagnosis tool for the start-up, analysis, monitoring, troubleshooting and service/maintenance of CAN bus systems: Latest measuring functions with easy and intuitive touchscreen operations Physical and logical analysis for determining the quality of the CAN network Measuring of Common-Mode-Voltage Mobile and ready for use Tap directly into a CAN bus and start measuring - without the need for a PC or laptop Simplified evaluation system using a combination of traffic lights and smileys From the developers of CAN-Bus Tester - world-wide CAN diagnostics market leaders Licenses for optional software apps : License, Node Measurement CAN License key for node related physical layer measurement in bus system CAN SW-22580-00 CANopen License key for node related physical layer measurement in bus system CANopen SW-22580-01 DeviceNet License key for node related physical layer measurement in bus system DeviceNet SW-22580-02 SAE J1939 License key for node related physical layer measurement in bus system SAE J1939 SW-22580-03 License Bus Wiring License key for bus wiring measurements SW-22580-10 License Protocol monitor License key for protocol monitor CAN (transmit/ receive) SW-22580-11 Property Value The information herein is subject to change without notice. General parameters and overview of functions Bus systems CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325–2), SAE J1939 Bit sampling 64-fold, 10240 sampling points Bit timing Adjustable BTL cycles (tq), sample point and resynchronization jump width (SJW) Supported baud rates Depending on bus system: 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s Additionally user-defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s Automatic detection via baud rate scan, bit timing adjustable Bus status Bus traffic detection (display: dominant, recessive, not defined, bus traffic) Display of the Bus traffic load (0 … 100 %) characteristic, minimum and maximum value saving Bus errors Display of detected frame errors Distinction between active and passive error frames (0 … >50,000), trend chart Bus voltages Display of the optional CAN supply voltage and shield voltage Characteristic, minimum and maximum value saving Common mode voltage Acquisition of the maximum voltage offset between the individual bus nodes CAN level (absolute /differential) Acquisition and evaluation of the differential and absolute CAN levels of all bus nodes during operation Node measurement Node related measurements Quality value (signal quality), Disturbance-free voltage range, Edge steepness (falling and rising) and Oscilloscope display with message frame analysis Online Trigger Error analysis with adjustable values, variable time slices and trigger function Protocol monitor Send and receive of CAN messages Electrical parameters Power supply and battery* Integrated, rechargeable lithium-ion battery External power input: SELV d.c. voltage 14 V, internal fused with 2.5 A Operating with the supplied 35 W wide-range power supply unit only (SAW-14.0–2500) Times-to-empty: Standby: up to 500 hours Use: up to 36 hours Measuring: up to 6 hours Charge times: Quick charge to 80% in approx. 1 h Full charge in approx. 2 h Potential difference between the CAN bus and USB connections > 500 V AC Voltage between any two terminals of the CAN connection or external ground, resp. > ±30 V DC Measurements Quality value Range : 0,0 % … 100,0 % Resolution : 0,1 % Accuracy (typ.) : Edge steepness Range : 0/64 … 64/64 Resolution : 1/64 .Accuracy (typ.) : Disturbance-free voltage range Range : -0,75 V … +3,25 V Resolution : 0,05 V Accuracy (typ.) : 1,90 % ±100 mV Measuring of the differential voltage Range : -0,75 V … +3,25 V Resolution : 0,01 V Accuracy (typ.) : 0,50 % ±10 mV (calibrated) Measuring of the absolute voltage Range : -5,00 V … +10,00 V Resolution : 0,05 V Accuracy (typ.) : 0,50 % ±50 mV (calibrated) Measuring of the shield voltage Range : -10,0 V … +1,0 V Resolution : 0,1 V Accuracy (typ.) : 0,25 % ±100 mV (calibrated) Measuring of the CAN supply voltage Range : 0.0 V … 32,0 V Resolution : 0,1 V Accuracy (typ.) : 0,25 % ±100 mV (calibrated) Measuring of the loop resistances Range : 0 Ω … 100 Ω 100 Ω … 1000 Ω Resolution : 0,1 Ω 1,0 Ω Accuracy (typ.) : 0,85 % ±0,2 Ω 0,85 % ±2,0 Ω Measuring of the cable length Range : 2 m … 1000 m Resolution : 1 m Accuracy (typ.) : 5 % ±2 m (signal propagation delay: 4.5 ns/m) Mechanical parameters Power supply unit connection Extra-low voltage socket CAN connection 9‑pin D‑Sub connector PC connection Self-powered device to USB Specification 2.0, full speed, in addition, electrically isolated Connection of a drive for exchange of measuring data (USB mass storage device) Housing Aluminum housing, cover glass Ambient conditions Operation temperature: 5 °C … 40 °C Storage temperature: ‑20 °C … 60 °C Atmospheric humidity: 20 % … 80 %, non-condensing Degree of protection of the housing IP20 to EN 60529 Dimensions 186 mm x 102 mm x 37 mm Weight Approx. 860 g CE conformity to EC Directive 2006/42/EC EC Directives RL 2011/65/EG Restriction of the use of certain hazardous substances (RoHS) RL 2012/19/EG Waste Electrical and Electronic Equipment RL 2006/95/EG Low Voltage Directive (LVD) RL 2004/108/EG EMC Directive Harmonized standards EN 60950–1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 Information technology equipment. Safety. General requirements EN 61000-32:2006 +A1:2009 +A2:2009 Limits – Limits for harmonic current emissions EN 61000–3-3:2008 Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current 16 A per phase and not subject to conditional connection EN 55011:2009 +A1:2010 Radio-frequency disturbance characteristics – Limits and methods of measurement EN 61000 – 6‑2:2005 Generic standards – Immunity for industrial environments EN 61000 – 6‑4:2007 +A1:2011 Generic standards – Emission standard for industrial environments EN 61326–1:2006 Electrical equipment for measurement, control and laboratory use – EMC requirements Flyer CANtouch® CANtouch® Flyer in PDF format Datasheet CANtouch® CANtouch® Datasheet in PDF format Manual CANtouch® CANtouch® Manual in PDF format Video CANtouch® CANtouch® Product Video
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2025
$3,920.00