
$84.69
See if it's really the one
Search with this product to compare it, find similar styles, or turn up something better before deciding.
Beverage-Air 502-111A Freezer Temperature Control This commercial replacement temperature control for Beverage-Air 502-111A is intended for compatible commercial undercounter and worktop freezers. The mechanical thermostat uses an 18-inch capillary sensing system and has a published nominal control range of -12°F to 18°F . The control responds to temperature at its sensing location and operates the cooling-control circuit according to the equipment's design. Correct selection depends on the original control reference, sensing arrangement, electrical ratings, and mounting configuration. Specifications OEM part number reference: Beverage-Air 502-111A Part classification: Commercial replacement part Part type: Mechanical temperature control / freezer thermostat Control style: Capillary-type cold control Capillary length: 18 inches Published nominal control range: -12°F to 18°F Documented application: Selected Beverage-Air undercounter and worktop freezers Temperature-range clarification: The published range describes the control's reference specification. It is not a recommended food-storage setting or a guarantee that the cabinet will maintain a particular temperature. Follow the equipment manufacturer's operating requirements and verify actual cabinet temperature after service. Documented Beverage-Air Applications Beverage-Air parts documentation identifies 502-111A for these legacy freezer configurations: Undercounter freezers: UCF27A, UCF48A Worktop freezers: WTF27A, WTF48A Confirm fitment before ordering: Match the complete equipment model and serial number, original control reference, and installed sensing arrangement. These references do not establish compatibility with every production revision, similarly named model, or later HC version. Symptoms That May Require Control Inspection The cooling circuit does not respond as expected when the sensed temperature changes. Cabinet temperature remains outside the equipment's specified operating range. The control cycles inconsistently after other operating conditions have been checked. The control body, terminals, adjustment mechanism, or capillary assembly is damaged. These symptoms do not confirm a thermostat failure by themselves. Airflow restrictions, dirty coils, evaporator icing, door-seal problems, defrost faults, and refrigeration-system issues can also affect cabinet temperature. Before You Order Confirm the original control reference is 502-111A , or obtain a verified replacement recommendation for your exact equipment. Record the complete Beverage-Air model and serial number. Compare the capillary length, sensing location, and required routing. Match the adjustment shaft, mounting arrangement, terminal configuration, and electrical contact ratings. Check the replacement control's label and documentation for its specific switching characteristics. Confirm whether any required knob, bracket, or mounting hardware is supplied or must be retained separately. Installation and Service Considerations Installation should be performed by a qualified commercial refrigeration technician with electrical power disconnected. Follow the equipment wiring diagram and preserve the specified sensing-element position and capillary routing. Do not cut, splice, sharply kink, or crush the capillary. After installation, verify control operation and actual cabinet temperature through normal operating cycles before returning the equipment to service. Frequently Asked Questions What is Beverage-Air 502-111A used for? 502-111A is a temperature-control reference used on documented Beverage-Air freezer configurations. It operates as a mechanical thermostat within the equipment's cooling-control system. Which Beverage-Air models are documented for this control? The manufacturer parts manual identifies UCF27A, UCF48A, WTF27A, and WTF48A configurations. Confirm the complete model, serial number, original control, and replacement specifications before ordering. Does the -12°F to 18°F range describe the cabinet's storage temperature? No. It is the published nominal control range. Actual cabinet temperature depends on the equipment design, sensing location, control adjustment, and operating condition. Use the equipment manufacturer's specified storage-temperature requirements. What does the 18-inch capillary do? The capillary is part of the thermostat's sealed temperature-sensing system. Its length and routing allow the sensing portion to reach the required location. It is not an electrical wire and must not be shortened or spliced. Will replacing this thermostat fix every temperature problem? No. A technician should confirm that the control is faulty and inspect other possible causes, including airflow, coil condition, door sealing, defrost operation, and refrigeration-system performance. Can I substitute another Beverage-Air thermostat that looks similar? Appearance alone does not establish compatibility. Compare the verified replacement reference, electrical ratings, switching characteristics, mounting details, adjustment shaft, and capillary arrangement. Should a refrigeration technician install this control? Yes. Correct wiring, sensing-element placement, and operating checks are necessary. A qualified technician should install the control and verify the equipment's temperature performance after replacement. Related Parts and Identification Help Browse our Beverage-Air commercial refrigeration parts or read our Beverage-Air temperature-control troubleshooting and identification guide . Need help confirming the correct control? Call 631-873-0509 with your equipment model, serial number, and a clear photo of the original control label. U.S. shipping: Available shipping options and charges are displayed at checkout.
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2026
$84.69