
$761.25
See if it's really the one
Search with this product to compare it, find similar styles, or turn up something better before deciding.
NC, C, NO] which are used to indicate general loop/ system trouble. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the eight (8) outputs. It provides a programmable LCD display interface, plus an ethernet port interface for remote programmability and monitoring. Specifications Agency Listings Dimensions & Weight Documentation Input Power input: 120VAC, 60Hz, 4.8A. Two (2) Class A or two (2) Class B FACP inputs. Input Ratings for - INP1 and INP2: 8-30VDC 6.5mA max from FACP. 12V 6.5mA, 24V 6.5mA from FACP. Two (2) configurable inputs trigger via Class A or Class B FACP signal circuits (polarity reversal) or dry contacts. Outputs Voltage: 24VDC regulated power-limited NACs. Output power: 10A max. total alarm current. 7A max. stand-by without battery back-up. 1A with battery back-up including Aux. output (0.45A for Canadian applications). 2.5A max current per output. One (1) auxiliary output rated at 1A (regulated, battery backed up). 0.45A for Canadian applications. Any NAC can be configured as an Aux. output with or without battery back-up (special application only). When set as Aux. output, the output is not supervised. Use UL Listed end of line device for the applications if supervision is required. Programmable supervised indicating circuit outputs: Eight (8) Class B or Four (4) Class A, or any combination of Class A and Class B circuits. Thermal and short circuit protection with auto reset. Supervision AC fail supervision (form “C” contact, 1A/28VDC). Battery presence and low battery supervision (form “C” contact, 1A/28VDC). AC local dry contact output (form “C” contact, 1A/28VDC). Battery Backup Built-in charger for sealed lead acid or gel type batteries. Automatic switchover to stand-by battery when AC fails. Zero voltage drop when switching over to battery backup. Indicators (LED) LCD Display: Indicates trouble and conditions of operation Facilitates quick identification of a fault. Displays which output fault has occurred on. Special Features: Programmable LCD display interface. EOL resistor value is programmable by output. Ethernet port interface for remote programmability and monitoring. 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. Sync protocols include Potter, Gentex®, System Sensor® , and CooperWheelock®. Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit). Compatible with 12VDC or 24VDC fire panels. Output loop supervision directed to input 1 or input 2. Common trouble Dry N.C. output for reporting trouble to remote FACP. Ground fault detection - Ground fault maximum test impedance 1,000 Ohm. Ground fault Dry N.O. output to report ground fault to remote FACP. CO Temporal Code 4 (NFPA720) include Gentex® , Potter and System Sensor® devices. Temperature Operating: 0ºC to 49ºC (32ºF to 120ºF). Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF). Relative Humidity 85% +/- 5%. BTU/Hr. (approx.): 123 BTU/Hr.
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2026
$761.25