
$709.00
See if it's really the one
Search with this product to compare it, find similar styles, or turn up something better before deciding.
1.36 kg] Compliance CE: EMC Directive – Class A EN 55032 & EN 55024, LV Safety Directive EN 62368-1; RoHS Compliant; FCC Part 15 Class; Industry Canada ICES-3 Class A; IEEE 802.3 Compliant; TAA Compliant Warranty 5 Years Limited Part Number 011309 *Dimensions are measured from the perspective of the product being upright with the front of the product facing you. FAQs How do I update my firmware? Go to the Downloads tab, click on the serial number range matching your device and download the firmware compatible with it. To update the firmware, unzip the file and log in to the web GUI for the device you are trying to upgrade. Navigate to the Firmware tab and browse for the firmware file you just downloaded. Select and upload that file. Do not reboot, the device will do it for you. For more information, please check your product’s Operations Guide, also available under the Downloads tab. PLEASE NOTE: Firmware is not backwards compatible for V3 devices. If you are downgrading or trying to update a pre-V3 device, please contact CyberData’s Technical Support Department first to ensure the device does not get damaged. We also recommend you export a copy of your current configuration BEFORE updating, should a loss of power or another issue occur that would potentially lose your settings. Is this device compatible with my service provider or IP-PBX server? CyberData VoIP products are compatible with IP-PBX servers that support standard SIP protocol. You can find a full list of IP-PBX servers that CyberData products have been validated on by going to Connecting to Compatible IP-PBX Servers. If you do not see your IP-PBX on this list, feel free to contact CyberData’s Technical Support Department for more information. What is multicast? IP multicast is a technique for one-to-many communication over a local IP network. IGMP multicast is sent via UDP packets from a multicast server to a multicast receiver. This stream scales to a larger receiver population by not requiring prior knowledge of who or how many receivers there are. Multicast uses network infrastructure efficiently by requiring the source to send a packet only once, even if it needs to be delivered to many receivers. The network replicates the packet in order to reach multiple receivers only when necessary. Multicast is a great alternative to SIP registration as it does not require that the recipient of the stream to register as an extension on an IP-PBX server. CyberData products support both regular IGMP multicast as well as proprietary Polycom Group Paging. Which IP Phones do you recommend for setting up a Peer to Peer SIP call with this device? See SIP Point-To-Point Configuration How loud is the speaker on the Intercom? The average Intercom volume level is 9 SPL using the standard 1KHz test tone normalized at 0dB and yields 93dB output at 1 meter. How can I prevent water or weather damage to the device if it is in a vulnerable location? Refer to “Connecting and Sealing the SIP Outdoor Intercom” on the Intercom Quick Reference Placemat. For additional support or answers to questions not covered on this page, who should I contact? CyberData’s Technical Support Department What type of relay does the intercom have? CyberData's line of intercoms have a normally open, temporarily closed style relay for use with most door strikes. If the inverse, normally closed temporarily open, is required please use one of CyberData's Door Strike Relay accessory products. What is the maximum rating for the intercom's relay? CyberData Intercoms onboard relays are rated up to 1 amp at 30 volt DC. Is the circuit board on the intercom IP rated? The circuit boards in CyberData's intercoms are not IP rated and rely on the IP rating of their enclosure to protect the board. Installation Typical Installation: Door Entry/Access Control Typical Installation: Auxiliary Strobe Kit Intercom to Auxiliary RGB Strobe Kit Connections Connections Remote Switch Connection Connecting to non-inductive type loads (Devices Less than 1A at 30 VDC) This relay can be used to trigger low current devices like strobes and security camera input signals as long as the load is not an inductive type and the relay is limited to a maximum of 1 Amp @ 30 VDC. Connecting to inductive type loads (Door Strike Intermediate Relay Module) We highly recommend that inductive load and high current devices use our Door Strike Intermediate Relay Module product (CD# 011269). Connecting to inductive type loads (Networked Dual Door Strike Relay) We highly recommend that inductive load and high current devices use our Networked Dual Door Strike Relay product (CD# 011375). Flush Mounting Rear Conduit Wall Mounting Bottom Conduit Wall Mounting Gooseneck Mounting 1 Gooseneck Mounting 2 Bottom Conduit Connection Rear Conduit Connection Grounding Network Cable Downloads Documentation Documentation Description Date PDF Datasheet DATE:11/2/22 PDF Quick Start Guide DATE:2/7/25 PDF Quick-Reference Placemat DATE:9/1/23 PDF Operations Guide (firmware v22.0) DATE:11/19/24 PDF CE Declaration of Conformity DATE:2/23/17 Connecting to Compatible IP-PBX Servers Firmware, Drivers & Utilities TERMINUS ZIP Firmware 22.0.2 *Note* You must upgrade to v22.0.1 before going to this version. DATE:5/12/25 TERMINUS ZIP Firmware 22.0.1 *Note* Upgrade will take 6 minutes to complete and cause your device to reboot twice. Device cannot revert to previous versions. DATE:11/19/24 ZIP The Discovery Utility scans the network and reports back any found VoIP devices that are attached to the physical network.
Have a question about this?
We currently ship within the US, with more countries coming soon.
Final cost and dates are confirmed at checkout.
🇺🇸 Ship from USA · On Agora since 2024
$709.00